EDX-100A
- Recommended sensors:










Compact and Lightweight, up to 128 channels measurement
Available with 1, 2 or 4 slots, the EDX-100A is a universal recorder that enables flexible configuration and free arrangement while ensuring multiple functions. The wide application range extends from small-scale measurement of 8 channels to large-scale measurement of up to 128 channels by connecting 4 units of the EDX-100A.For PC connection, LAN and USB ports are provided. The LAN port enables the PC to control up to 4 units of EDX-100A, while the USB port ensures easy connection between the EDX-100A and the PC.In addition, the EDX-100A can be operated as a stand-alone unit with no PC connected. A compact flash memory card enables condition setting and data collection.To respond to the need for a wide variety of measurements, 6 different types of conditioner cards are available.
Features
- Compact and lightweight
- Available with 1, 2 and 4 slots
- LAN port for establishing multichannel network (max. 128 channels)
- USB port for easy connection to the PC
- Operable as a stand-alone unit
- High-speed sampling at 100 kHz (10 kHz for 16-channel measurement)
- CAN data acquisition possible with CAN-40A/41A conditioner card mounted
- Various conditioner cards available
- TEDS compatible
- Voice memo can be recorded by using an optional dedicated remote control unit.
- Dynamic data acquisition software DCS-100A is included in standard accessories.
- Measured data is saved in KYOWA standard KS2 format and can be analyzed with optional data analysis software DAS-100A.
-
Operates on 10 to 18 VDC.
※For the data analysis software DAS-200A .
PDF download
- EDX-100A (359.86 kB)
Specifications
Models
| Model | Card Slots | Max. Number of Analog Input Channels | Remark |
|---|---|---|---|
| EDX-100A-1 | 1 | 8 | |
| EDX-100A-2 | 2 | 16 | |
| EDX-100A-4 | 4 | 32 | |
| EDX-100A-1H | 1 | 8 | With handle grip |
| EDX-100A-2H | 2 | 16 | |
| EDX-100A-4H | 4 | 32 |
| Number of Input Channels | Refer to table above. |
| Analog Input | Provided by optional conditioner cards (common to EDX-2000A). |
| For the conditioner cards, | |
| CAN Data Input | Povided by the optional CAN-40A or CAN-41A |
| Voice Memo Input | 1 channel. |
| An optional dedicated remote control unit RCU-41A enables recording of voice memo during measurement in manual mode. | |
| Reproduction of recorded voice memo requires an optional data analysis software DAS-100A. | |
| Sampling Method | Simultaneous sampling of all channels |
| Sampling Frequency Selection Systems |
1-2-5 sysem in a range of 1 Hz to 100 kHz 2 n system in a range of 2 Hz to 65536 Hz |
| Sampling Frequency (1-2-5 system) | 1 Hz to 100 kHz for 1-channel measurement |
| 1 Hz to 50 kHz for 3-channel measurement | |
| 1 Hz to 20 kHz for 8-channel measurement | |
| 1 Hz to 10 kHz for 16-channel measurement | |
| 1 Hz to 5 kHz for 32-channel measurement | |
| 1 Hz to 1 kHz for CAN data measurement | |
| Data Storage | Compact flash memory card |
| (128 MB to 8 GB; 45x speed or higher) | |
| Up to 2 GB data for 1 time of measurement | |
| Setting Conditions | Online : From the PC through LAN or USB port |
| Offline : By reading from the CF card which has measuring conditions written with the DCS-100A data acquisition software | |
| Saving Conditions | Amplifier setting conditions and measuring conditions are saved in the internal nonvolatile memory, enabling immediate setup with previous conditions upon power-on. |
| Measurement Modes | |
| Manual | Data recording is manually started/stopped or stopped when data is recorded to a preset number of measured data. |
| Manual mode allows recording of voice memo during data recording. | |
| Trigger | Data recording is automatically started when the preset trigger condition is satisfied. |
| Note that any CAN data cannot be used as the trigger condition. | |
| Interval | Data recording is periodically made at preset intervals. |
| Manual Start/Stop of Data Recording | Possible through the PC or by pressing the switch on the front panel or from the dedicated remote control unit |
| Balance Adjustment | Strain input channels can be balanced by pressing the BAL. |
| switch on the front panel or from the dedicated remote control unit or through the PC. | |
| Saved Data Format | KYOWA standard format KS2, which enables data analysis |
| with the optional data analysis software DAS-100A | |
| Collecting Data | LAN or USB port enables online data transfer to the PC, |
| while CF card enables offline data transfer. | |
| TEDS Function | Usable when the EDX-100A is under the online control of the PC. Compatible conditioner cards are CDV-40B(-F),DPM-42A(-F) and CCA-40A(-F). The suffix F denotes that the card is equipped with 8th order Butterworth antialiasing filter. |
| Synchronous Operation | Synchronous cable enables cascade connection of up to 4 units of the EDX-100A. |
| While data is recorded as a separate file in the CF card inserted into each unit, files of all cards can be combined into a singlefile after online or offline data transfer to the PC. | |
| Analog Output | Except for CDV-40B(-F) and CAN-40A, conditioner cards provide an analog output connector, enabling voltage monitoring (5 V FS). |
| CF Card Slot | 1 (for data recording and condition setting) |
| Communication Ports | LAN and USB (for control and data transfer), switchable |
| LAN I/F | 10BASE-T/100BASE-TX Connector: |
| RJ45 modular jack | |
| USB I/F | Conforms to USB 2.0 (high speed). |
| Connector: Series B receptacle | |
| Operation Switches | REC/PAUSE : Start/pause data recording. |
| STOP : Stop data recording. | |
| BAL. : Execute balance adjustment. | |
| BAL. : Execute balance adjustment. | |
| ID : Set ID No. of EDX-100A. | |
| LAN/USB : Switch communication port. | |
| Indicators | Operation status indicator LEDs: 7 |
| Channel status indicator LEDs: The number corresponds to the number of channels provided. | |
| External Control Connectors | CONT IN and CONT OUT(for remote control and synchronous operation) |
| Operating Temperature Range | 0 to 50℃ |
| Operating Humidity Range | 20 to 90% RH (noncondensing) |
| Storage Temperature Range | -20 to 60℃ |
| Vibration Resistance | 29.42 m/s 2 (3 G), 5 to 55 Hz (when operating) |
| 49.03 m/s 2 (5 G), 5 to 55 Hz (when not operating) | |
| Shock Resistance | 196.1 m/s 2 (20 G)/11 ms |
| EMC Standards | IEC61326-1 Class A) |
| Safety standards | IEC61010-1 (set certificate Ⅱ, pollution degree 2) |
| Power Supply | 10 to 18 VDC |
| Connector: RM12BRD-4PH (Hirose) | |
| DC power supply or optional dedicated AC adapter is required. | |
| Current Consumption | EDX-100A-1: Approx. 1.2 A (when operated on 12 VDC with 1 CDV-40B card mounted and full load applied) |
| EDX-100A-2: Approx. 1.8 A (when operated on 12 VDC with EDX-100A-2: Approx. 1.8 A (when operated on 12 VDC with | |
| EDX-100A-4 Approx. 2.8 A (when operated on 12 VDC with 4 CDV-40B cards mounted and full load applied) | |
| Dimensions | EDX-100A-1: 70.0(W) x 132.5(H) x 255(D) mm |
| EDX-100A-2: 92.5(W) x 132.5(H) x 255(D) mm | |
| EDX-100A-4: 137.5(W) x 132.5 (H) x 255(D) mm | |
| excluding protrusions | |
| Weight, Approx | EDX-100A-1: 1.6 kg (1.7 kg with 1 CDV-40B card mounted) |
| EDX-100A-2: 1.8 kg (2.0 kg with 2 CDV-40B cards mounted) | |
| EDX-100A-4: 2.0 kg (2.6 kg with 4 CDV-40B cards mounted) | |
Standard Accessory
Power cable P-57,USB cable N-38
Dynamic Data Acquisition Software DCS-100A
CF card
Optional Accessories
USB cable (N-39) 2 m long
Synchronous cable N-95 2 m long
AC adapter UIA 345-12
Input: 100 to 240 VAC, 50/60 Hz, 1.2 A
Output: 2 VDC, 3.8 A
Dummy panel EDX-DUMMY
Remote Control Unit
| Control Buttons | RCU-41A |
| (1) REC/PAUSE : Start/pause data recording. | |
| (2) STOP : Stop data recording. | |
| (3) BAL. : Execute balance adjustment. | |
| (4) VOICE MEMO : Record voice memo. | |
| LED Indicators | REC/PAUSE, BAL |
| Cable | 1.5 m long |
| (to be connected to CONT IN connector of EDX-100A | |
| Dimensions | 35(W) x 110(H) x 20(D) mm (excluding protrusions) |
| Weight | Approx. 200g |
Registration