• Products
  • Support
  • Technical information
  • Download
  • Corporate information

Home > Products > Automotive Test Equipment > Crash Test > ASDH-A

ASDH-A NEW

Miniature Crash Test Acceleration Transducer
  • 9807m/s 2
  • 19613m/s 2
ASDH-A

Mountable to Crash Test Dummies
and Car Bodies

Features

  • Undamped design ensures minimal influence to the
    frequency response and phase characteristic.
  • 2 models are available for selection of the sensitive
    axis,vertical or horizontal to the mounting surface.
  • Centroid is set at the tip of mainframe for triaxial
    configuration of accleration transducers 

PDF download

CAD data download

Specifications

Model Name Measuring
 Direction
Rated Capacity
(Reference)
Installation Resonance
 Frequency
ASDH-A-1KV Vertical ±9807m/s 2 (±1000G) 23kHz or more
ASDH-A-1KH Horizontal ±9807m/s 2 (±1000G) 23kHz or more
ASDH-A-2KV Vertical ±19613m/s 2 (±2000G) 26kHz or more
ASDH-A-2KH Horizontal ±19613m/s 2 (±2000G) 26kHz or more

Performance

Rated Capacity Refer to Table below
Nonlinearity Within±0.5%RO
Hysteresis Within±0.5%RO
Rated Output 1.2 mV/V (2400μm/m) or more
Peak-to-Peak Sensitivity Error 1%RO or less

Environmental Characteristics

Safe Temperature Range -20 to 60℃
Compensated Temperature Range 5 to 40℃
Temperature Effect on Zero Within±0.5%RO/℃±Within±0.5%RO/℃
Temperature Effect on Output Within±0.1%/℃

Electrical Characteristics

Safe Excitation Voltage 12V AC or DC
Recommended Excitation Voltage 2 to 10V AC or DC
Input Resistance 0.5 to 1.0kΩ
Output Resistance 0.5 to 1.0kΩ
Cable 4-conductor(0.05mm2)vinyl shielded cable,
7mlong,2.6mm,terminated with connector plug(R05-PB5M)

Mechanical Properties

Safe Overload Rating 200%
Frequency Respose Range DC to 4kHz(sensitivity deviation±5%)(23℃)
Resonance Frequency Refer to Table below
Transverse Sensitivity 1% RO or less
Weight Approx 1.4g

Back to Top

Registration

Please register for our website support when downloading files or documents.

New registration