LBT-A-20KNSA1
Seat Belt Tension Transducer
LBT-A-20KNSA1
Measuring Impact-Initiated Tesion
of Seat Belt in Crash Tests
Using a strain gage, the LBT-S-20KNS1 detects the
impact-initiated tension applied through the dummy
to the seat belt. The aluminum alloy frame makes it
lightweight.
PDF download
- LBT-A-20KNSA1 (196.41 kB)
Specifications
Performance
| Rated Capacity | 20 kN |
| Nonlinearity | Within ±2%RO |
| Rated Output | Within ±2%RO |
Environmental Characteristics
| Safe Temperature Range | 0 to 60℃ |
| Compensated Temperature Range | 10 to 50℃ |
| Temperature Effect on Zero | Within ±0.1%RO/℃ |
| Temperature Effect on Output | Within ±0.1%/℃ |
Electrical Characteristics
| Safe Excitation Voltage | 10V AC or DC |
| Recommended Excitation Voltage | 1 to 5V AC or DC |
| Input Resistance | 350Ω±2% |
| Output Resistance | 350Ω±2% |
| Cable | 4-conductor (0.08 mm2) heat-resistant vinyl shielded cable, |
| 3.2 mm diameter by 7 m long, terminated with R05-PB5M | |
| connector plug (Shield wire is not connected to the body.) |
Mechanical Properties
| Mechanical Properties | 100% |
| Enclosure | Metallic finish |
| Weight | Approx. 130 g (excluding cable and connector) |
| Others | Calibrated using KYOWA standard seat belt. |
| Not waterproofed |
Note) Characteristic values are based on Kyowa calibration method
and conditions.
※ It is acceptable to calibrate with supplied seat belt.
Registration