LCF-2TA
Femur Load Cell
LCF-2TA
For Femur of a Crash Dummy
Mounted to the femur of a crash dummy such as
Hybrid III, the LCF-2TA detects impact-initiated load to
the femur.
Features
-
Conforms to Federal Motor Vehicle Safety Standard 208
as a sensor to obtain injury rating.
PDF download
- LCF-2TA (164.66 kB)
Specifications
Performance
| Rated Capacity | 20 kN |
| Nonlinearity | Within ±0.4%RO |
| Hysteresis | Within ±0.4%RO |
| Repeatability | 0.2%RO or less |
| Rated Output | 1 to 1.5 mV/V (2000 to 3000μm/m) |
Environmental Characteristics
| Environmental Characteristics | -10 to 70℃ |
| Compensated Temperature Range | 0 to 60℃ |
| Temperature Effect on Zero | Within ±0.1%RO/℃ |
| Temperature Effect on Output | Within ±0.1%/℃ |
Electrical Characteristics
| Safe Excitation Voltage | 10V AC or DC |
| Recommended Excitation Voltage | 1 to 10V AC or DC |
| 1 to 10V AC or DC | 350Ω±3% |
| Output Resistance | 350Ω±3% |
| Output Resistance | 4-conductor (0.65 mm 2 ) vinyl shielded cable, 4 mm diameter by 5 m |
| ong, bared at the tip (Shield wire is not connected to the body.) |
Mechanical Properties
| Safe Overload Rating | 120% |
| Weight | Approx. 700 g |
Registration
Please register for our website support when downloading files or documents.