• Products
  • Support
  • Technical information
  • Download
  • Corporate information

Products > Civil Engineering / Construction > BEM-A

BEM-A

Soil Pressure Transducers

50 kPa to 1 MPa

BEM-A

A pressure-sensing surface 80mm in diameter.The stainless steel design enables marine applications.
The BEM-A series is underground soil pressure transducers with a pressure-sensing surface 80 mm in diameter. The strainless steel design enables marine applications.

Features

  • Dual diaphragm design with the pressure medium sealed between the pressure-sensing surface and strain gage-bonded diaphragm enables transmission of minute displacement through enlargement.
  • Stainless steel construction

PDF download

Specifications

Performance

 

Model Rated Capacity
BEM-A-50KP 50kPa
BEM-A-100KP 100kPa
BEM-A-200KP 200kPa
BEM-A-500KP 500kPa
BEM-A-1MP 1MPa

Nonlinearity

 

Within±2% RO (BEM-A-50KP to 200KP)
Within 1% RO (BEM-A-500KP & 1MP)
Hysteresis Within±1% RO
Rated Output 0.25 mV/V (500μm/m) or more (BEM-A-50KP)
0.5 mV/V (1000μm/m) or more (BEM-A-100KP)
1 mV/V (2000μm/n) or more (BEM-A-200KP to 1MP)

Environmental Characteristics

Safe Temperature Range -20 to 80℃
Compensated Temperature Range -15 to 70℃
Temperature Effect on Zero Balance Within±0.5% RO/℃ (BEM-A-50KP)
Within±0.3% RO/℃ (BEM-A-100KP & 200KP)
Within±0.2% RO/℃ (BEM-A-500KP & 1MP)
Temperature Effect on Output Within±0.1%/℃

Electrical Characteristics

Safe Excitation Voltage 10V AC or DC
Recommended Excitation Voltage 2 to 8V AC or DC
Input Resistance 350Ω±1%
Output Resistance 350Ω±1%
Cable 4-conductor (0.5 mm 2 ) chloroprene cable, 8 mm diameter by
1 m long, bared at the tip

Mechanical Properties

Safe Overload Rating 120%
Weight Approx. 1 kg