BEM-A
Soil Pressure Transducers
50 kPa to 1 MPa
BEM-A
A pressure-sensing surface 80mm in diameter.The stainless steel design enables marine applications.
The BEM-A series is underground soil pressure transducers with a pressure-sensing surface 80 mm in diameter. The strainless steel design enables marine applications.
Features
- Dual diaphragm design with the pressure medium sealed between the pressure-sensing surface and strain gage-bonded diaphragm enables transmission of minute displacement through enlargement.
- Stainless steel construction
PDF download
- BEM-A (149.86 kB)
Specifications
Performance
| Model | Rated Capacity |
|---|---|
| BEM-A-50KP | 50kPa |
| BEM-A-100KP | 100kPa |
| BEM-A-200KP | 200kPa |
| BEM-A-500KP | 500kPa |
| BEM-A-1MP | 1MPa |
|
Nonlinearity
|
Within±2% RO (BEM-A-50KP to 200KP) |
| Within 1% RO (BEM-A-500KP & 1MP) | |
| Hysteresis | Within±1% RO |
| Rated Output | 0.25 mV/V (500μm/m) or more (BEM-A-50KP) |
| 0.5 mV/V (1000μm/m) or more (BEM-A-100KP) | |
| 1 mV/V (2000μm/n) or more (BEM-A-200KP to 1MP) |
Environmental Characteristics
| Safe Temperature Range | -20 to 80℃ |
| Compensated Temperature Range | -15 to 70℃ |
| Temperature Effect on Zero Balance | Within±0.5% RO/℃ (BEM-A-50KP) |
| Within±0.3% RO/℃ (BEM-A-100KP & 200KP) | |
| Within±0.2% RO/℃ (BEM-A-500KP & 1MP) | |
| Temperature Effect on Output | Within±0.1%/℃ |
Electrical Characteristics
| Safe Excitation Voltage | 10V AC or DC |
| Recommended Excitation Voltage | 2 to 8V AC or DC |
| Input Resistance | 350Ω±1% |
| Output Resistance | 350Ω±1% |
| Cable | 4-conductor (0.5 mm 2 ) chloroprene cable, 8 mm diameter by |
| 1 m long, bared at the tip |
Mechanical Properties
| Safe Overload Rating | 120% |
| Weight | Approx. 1 kg |
Registration