BFD-A-TS
300 MPa
For stress measurement of reinforcing bar
The BFD-A-TS series transducers are designed for stress measurement of reinforcing bars whose nominal diameters are larger than those measured by the BF-CT series. The BFD-A-TS series is used by welding both ends to a reinforcing bar in the field. Select the model suitable for the diameter of the reinforcing bar. Each model provides a temperature measuring function to enable simultaneous measurement of stress and temperature.
Features
- For long-term stable measurement, the transducer proper features a special structure with inert gas filled in.
- The self-temperature-compensated strain gage used for the transducer enables measurement of temperature stress of the reinforcing bar.
PDF download
- BFD-A-TS (153.04 kB)
Specifications
Performance
| Performance | |
| Rated Capacity | 300MPa(1MPa=1N/mm 2 ) |
| (Please contact sales staff about rated capacity for 350 to 400MPa) | |
| Nonlinearity | Within±1% RO |
| Hysteresis | Within ±1% RO |
| Rated Output | 1.85 mV/V (3700 μm/m) or more |
| Temperature Measurement | |
| Rated Capacity | -30 to 70℃ |
| Measurement Error | ±0.5℃ (-30 to 70℃) |
| (Refer to Small-Sized Temperature Transducer BTS-100AT, here ) | |
Environmental Characteristics
| Safe Temperature Range | -30 to 80℃ |
| Compensated Temperature Range | -10 to 70℃ |
| Temperature Effect on Zero Balance | Within±0.1% RO/C |
| Temperature Effect on Output | Within±0.1%/℃ |
Electrical Characteristics
| Safe Excitation Voltage | 1Safe Excitation Voltage |
| Input Resistance | Input Resistance |
| Output Resistance | Output Resistance |
|
Cable
|
4-conductor (0.5 mm 2 ) chloroprene shielded cable, |
| 8 mm diameter by 1 m long, bared at the tip |
Mechanical Properties
| Safe Overload Rating | 110% |
| Nominal Diameter (Deformed Bar) | See table below |
| Material | Metallic finish |
Other
| Applicable Reinforcing Bar | SD345 (formerly, SD35) |
| Reinforcing-Bar | Please provide Reinforcing-Bar for BFD-A-51TS to Kyowa |
| 2 pieces x 335mm long | |
|
Calibration
|
The BFD-A-51TS is calibrated by applying to a single |
| sensing section, compressive load (approx. 600 kN) equivalent to the | |
| rated capacity of 300 MPa and compressive load (approx. 670 kN) | |
| equivalent to the safe overload rating |
Registration
Please register for our website support when downloading files or documents.