LC-E
General-Purpose Compression Load Cells
- Recommended category:

2 & 5 MN
LC-E
High Stability and Hermetically
Sealed Structure with Inert Gas
Filled in.
Inert Gas is filled in the detector portion, thereby
preventing aging deterioration and ensuring a stable
and reliable operation.
Features
※Watertight type (JIS C 0920) is also available.
※TEDS-installed versions can be manufactured.Inquiries are welcome.
PDF download
- LC-E (273.73 kB)
Specifications
| Model | Rated Capacity |
Natural Frequency (Approx.) |
Weight (Approx.) |
|---|---|---|---|
| LC-200TE | 2MN | 3.5kHz | 49kg |
| LC-500TE | 5MN | 4kHz | 65kg |
※Note: Mount Base CA-B is included in standard accessories.
Watertight model conforming to JIS C 0920 can be manufactured.
Inquiries
are welcome.
Performance
| Rated Capacity | See table below. |
| Nonlinearity | Within±0.5% RO |
| Hysteresis | Within±0.2% RO |
| Repeatability | 0.1% RO or less |
| Rated Output | 2 mV/V (4000μm/m) ±1% |
Environmental Characteristics
| Safe Temperature Range | -30 to 85℃ |
| Compensated Temperature Range | -10 to 70℃ |
| Temperature Effect on Zero Balance | Within±0.005% RO/℃ |
| Temperature Effect on Output | Within±0.005%/℃ |
Electrical Characteristics
| Safe Excitation Voltage | 20V AC or DC |
| Recommended Excitation Voltage | 1 to 10V AC or DC |
| Input Resistance | 350Ω±0.5% |
| Output Resistance | 350Ω±0.5% |
| Cable |
4-conductor (0.3 mm
2
) chloroprene shielded cable, 7.6 mm diameter by 5 m long, terminated with connector plug |
| (Shield wire is connected to mainframe.) |
Mechanical Properties
| Safe Overload Rating | 150% |
| Natural Frequency | See table below. |
| Weight | See table below. |
Registration