LC-V
Small-Sized Compression Load Cells
- Recommended category:







50 to 200 kN
LC-V
Compact and lightweight
Accuracy: 1/2000
Compact and lightweight design facilitates installation
into existing facilities. While accuracy of 1/2000
is ensured, the hermetically-sealed structure with
inert gas filled in enables highly stable and reliable
measurement. (Patented)
Features
● Hermetically sealed structure with inert gas filled in
● Service life: 10 million times or more
● BISELCOM gage is used.
PDF download
- LC-V (251.69 kB)
Specifications
| Model | Rated Capacity |
Natural Frequency (Approx.) |
Weight (Approx.) |
|---|---|---|---|
| LC-5TV | 50kN | 17kHz | 800g |
| LC-10TV | 100kN | 16kHz | 1.3kg |
| LC-20TV | 200kN | 15kHz | 2.6kg |
Performance
| Rated Capacity | See table below. |
| Nonlinearity | Within±0.05% RO |
| Hysteresis | Within±0.05% RO |
| Repeatability | 0.03% RO or less |
| Rated Output | 2.5 mV/V (5000μm/m) ±0.2% |
Environmental Characteristics
| Safe Temperature Range | -20 to 80℃ |
| Compensated Temperature Range | -10 to 70℃ |
| Temperature Effect on Zero Balance | Within ±0.003% RO/℃ |
| Temperature Effect on Output | Within ±0.003%/℃ |
Electrical Characteristics
| Safe Excitation Voltage | 20V AC or DC |
| Recommended Excitation Voltage | 1 to 10V AC or DC |
| Input Resistance | 350Ω±0.5% |
| Output Resistance | 350Ω±0.5% |
| Cable |
4-conductor (0.5 mm
2
) chloroprene shielded cable, 8.5 mm diameter by 5 m long, with press-fit terminal for 4 mm |
| (Shield wire is not connected to mainframe.) |
Mechanical Properties
| Safe Overload Rating | 150% |
| Natural Frequency | See table below. |
| Weight | See table below. |
| Protection Rating | IP67(Watertight type conforming to JIS C 0920) |