LCR-G-SA2
Small-Sized Large-Capacity Compression Load Cells
- Recommended category:




10 to 50kN
LCR-G-SA2
Compact, Lightweight,
Large Capacity Measurement
for Cylinder.
Since the diameter is small and the cable comes
from the bottom, LCR-G-SA2 series load cells can be
inserted into cylindrical object for measurement.
PDF download
- LCR-G-SA2 (245.72 kB)
Specifications
| Model | Rated Capacity |
Weight (Approx.) |
|---|---|---|
| LCR-G-10KNSA2 | 10kN | 100g |
| LCR-G-20KNSA2 | 20kN | |
| LCR-G-30KNSA2 | 30kN | |
| LCR-G-50KNSA2 | 50kN | 130g |
Performance
| Rated Capacity | See table below. |
| Nonlinearity | Within ±1% RO |
| Hysteresis | Within ±1% RO |
| Rated Output | 1 mV/V (2000μm/m) or more |
Environmental Characteristics
| Safe Temperature Range | -10 to 70℃ |
| Compensated Temperature Range | 0 to 60℃ |
| Temperature Effect on Zero Balance | Within±0.1% RO/℃ |
| Temperature Effect on Output | Within±0.05%/℃ |
Electrical Characteristics
| Safe Excitation Voltage | 7V AC or DC |
| Recommended Excitation Voltage | 1 to 2V AC or DC |
| Input Resistance | 350Ω±5% |
| Output Resistance | 350Ω±5% |
| Cable |
4-conductor (0.05 mm
2
) chloroprene shielded cable, 3 mm diameter by 5 m long, terminated with connector plug |
| (Shield wire is not connected to mainframe.) |
Mechanical Properties
| Safe Overload Rating | 120% |
| Weight | See table below |
| Material | Metallic |
Registration
Please register for our website support when downloading files or documents.