• Products
  • Support
  • Technical information
  • Download
  • Corporate information

Home > Products > Transducers > Loadcells > LCS-D

LCS-D

Explosion-proof construction Compression Load Cell
  • Recommended category:
  • 実験・研究
  • エネルギー

5 to 50kN

LCS-D

Dedicated Compression Load Cell
of Explosion-Proof Construction.

Features

※Please contact us for details

PDF download

Specifications   

Model Rated
Capacity
Natural Frequency
(Approx)
Weight
(Approx)
Lord-bearing
Unit
Movable
Saddle
Mounting
Base
LCS-500KD 5kN 4kHz 4kg --- --- CF-80
LCS-1TD 10kN 5.3kHz
LCS-2TD 20kN 6.2kHz 4kg CA-10B ER-5B CF-80
LCS-5TD 50kN 6kHz

Performance

Rated Capacity See table below
Nonlinearity Within ±0.2%RO
Hysteresis Within ±0.2%RO
Repeatability 0.2% RO or less
Rated Output 2mV/V ( 4000μm/m) ±0.2%

Environmental Characteristics

Safe Temperature Range -15 to 75℃
Compensated Temperature Range -10 to 70℃
Temperature Effect on ZERO Balance Within ±0.007%RO/℃
Temperature Effect on Output Within ±0.005%/℃
Explosion-proof Environmental Conditions Ambient Temperature : -10 to 40℃
Relative Humidity : 45 to 85%RH

Electrical Characteristics

Safe Excitation Voltage 15V AC or DC
Recommended Excitation Voltage 1 to 10V AC or DC
Input Resistance 350Ω±0.5%
Output Resistance 350Ω±0.5%
Cable 4-conductor (0.03mm 2 ) chloroprene shielded cable,
5mm diameter by 7.6m long, terminated with connector plug.
(Shield wire is not connected to mainframe)

Mechanical Properties

Safe Overload Rating 120%
Natural Frequency See table below
Weight See table below

Junction Box for Explosion - proof JBS-1C,4C

Back to Top

Registration

Please register for our website support when downloading files or documents.

New registration

Inquiries from the Web