Explosion-proof construction Compression Load Cell
- Recommended category:


5 to 50kN
LCS-D
Dedicated Compression Load Cell
of Explosion-Proof Construction.
Features
※Please contact us for details
PDF download
- LCS-D (288.97 kB)
Specifications
| Model |
Rated Capacity |
Natural Frequency (Approx) |
Weight (Approx) |
Lord-bearing Unit |
Movable Saddle |
Mounting Base |
|---|---|---|---|---|---|---|
| LCS-500KD | 5kN | 4kHz | 4kg | --- | --- | CF-80 |
| LCS-1TD | 10kN | 5.3kHz | ||||
| LCS-2TD | 20kN | 6.2kHz | 4kg | CA-10B | ER-5B | CF-80 |
| LCS-5TD | 50kN | 6kHz |
Performance
| Rated Capacity | See table below |
| Nonlinearity | Within ±0.2%RO |
| Hysteresis | Within ±0.2%RO |
| Repeatability | 0.2% RO or less |
| Rated Output | 2mV/V ( 4000μm/m) ±0.2% |
Environmental Characteristics
| Safe Temperature Range | -15 to 75℃ |
| Compensated Temperature Range | -10 to 70℃ |
| Temperature Effect on ZERO Balance | Within ±0.007%RO/℃ |
| Temperature Effect on Output | Within ±0.005%/℃ |
| Explosion-proof Environmental Conditions | Ambient Temperature : -10 to 40℃ |
| Relative Humidity : 45 to 85%RH |
Electrical Characteristics
| Safe Excitation Voltage | 15V AC or DC |
| Recommended Excitation Voltage | 1 to 10V AC or DC |
| Input Resistance | 350Ω±0.5% |
| Output Resistance | 350Ω±0.5% |
| Cable |
4-conductor (0.03mm
2
) chloroprene shielded cable, 5mm diameter by 7.6m long, terminated with connector plug. |
| (Shield wire is not connected to mainframe) |
Mechanical Properties
| Safe Overload Rating | 120% |
| Natural Frequency | See table below |
| Weight | See table below |
Junction Box for Explosion - proof JBS-1C,4C