LCX-A-ID
Small-Sized Compression Load Cells
- Recommended category:








500N~20kN
LCX-A-ID
Compact, Lightweight and Thin
Easy to Incorporate into Equipment
Compact and lightweight LCX-A-ID series load cells
can easily be incorporated into existing equipment.
PDF download
- LCX-A-ID (375.46 kB)
Specifications
| Model | Rated Capacity |
Natural Frequency (Approx.) |
|---|---|---|
| LCX-A-500N-ID | 500N | 24kHz |
| LCX-A-1KN-ID | 1kN | 29kHz |
| LCX-A-2KN-ID | 2kN | 37kHz |
| LCX-A-5KN-ID | 5kN | 24kHz |
| LCX-A-10KN-ID | 10kN | 28kHz |
| LCX-A-20KN-ID | 20kN | 37kHz |
Performance
| Rated Capacity | See table below. |
| Nonlinearity | Within±0.1% RO |
| Hysteresis | Within±0.1% RO |
| Repeatability | 0.05% RO or less |
| Rated Output | 1.0 mV/V (2000μm/m) or more (LCX-A-500N-ID) |
| 1.5 mV/V (3000μm/m) or more (LCX-A-1KN to 20KN-ID) |
Environmental Characteristics
| Safe Temperature Range | -20 to 80℃ |
| Compensated Temperature Range | -10 to 70℃ |
| Temperature Effect on Zero Balance | Within ±0.01% RO/℃ (LCX-A-500N-ID) |
| Within ±0.005% RO/℃ (LCX-A-1KN to 20KN-ID) | |
| Temperature Effect on Output | Within ±0.005%/℃ |
Electrical Characteristics
| Safe Excitation Voltage | 15V AC or DC |
| Recommended Excitation Voltage | 1 to 10V AC or DC |
| Input Resistance | 375Ω±5Ω |
| Output Resistance | 350Ω±3.5Ω |
| Cable |
6-conductor (0.08 mm2) chloroprene shielded cable, 4.4 mm diameter by 3 m long, terminated with connector plug to the transducer side and bared at the other side |
| (Shield wire is not connected to mainframe.) |
Mechanical Properties
| Safe Overload Rating | 150% |
| Safe Lateral Load Rating | 15% the rated capacity |
| Natural Frequency | See table below. |
| Material | SUS, metallic finish |
| Weight | Approx. 45 g (LCX-A-500N to 2KN-ID) (excluding cable) |
| Approx. 120 g (LCX-A-5KN to 20KN-ID) (excluding cable) | |
| Protection Rating | IP67 (Watertight structure conforming to JIS C 0920) |
Registration