LMR-S-SA2
- Recommended category:




2 to 20 kN
Compact,Lightweight, Low price,
Suitable for Load Distribution
Measurement
Compact and lightweight LMR-S-SA2 series load
cells can be used by merely putting or bonding on the
subject site or settng in a hollow. Major applications
include measurement of load distribution by using
multiple units, load measurement in pipe making mill
or where a measuring site or the weight of load cell
itself is limited.
Features
※TEDS-installed versions can be manufactured. Inquiries are welcome.
PDF download
- LMR-S-SA2 (227.53 kB)
Specifications
| Model | Rated Capacity |
|---|---|
| LMR-S-2KNSA2 | 2kN |
| LMR-S-5KNSA2 | 5kN |
| LMR-S-10KNSA2 | 10kN |
| LMR-S-20KNSA2 | 20kN |
※Users should be cautioned that operating conditions may adversely affect the
stated specifications.
Performance
| Rated Capacity | See table below. |
| Nonlinearity |
Within ±1% RO (LMR-S-2KNSA2 to 10KNSA2) Within ±2% RO (LMR-S-20KNSA2) |
| Hysteresis |
Within ±1% RO (LMR-S-2KNSA2 to 10KNSA2) Within ±2% RO (LMR-S-20KNSA2) |
| Repeatability | ±1% RO or less |
| Rated Output | 1 mV/V (2000 μm/m) or more |
Environmental Characteristics
| Safe Temperature Range | -10 to 60℃ |
| Compensated Temperature Range | 0 to 50℃ |
| Temperature Effect on Zero Balance | Within ±0.05% RO/℃ |
| Temperature Effect on Output | Within ±0.05%/℃ |
Electrical Characteristics
| Safe Excitation Voltage | 7V AC or DC |
| Recommended Excitation Voltage | 1 to 2V AC or DC |
| Input Resistance | 350Ω±2% |
| Output Resistance | 350Ω±2% |
| Cable |
4-conductor (0.035 mm
2
) vinyl shielded cable, 1.7 mm diameter by 2 m long, bared at the tip (Shield wire is connected to mainframe.) |
Mechanical Properties
| Safe Overload Rating | 120% |
| Natural Frequency | Approx.50kHz |
| Weight | Approx.25g |
| Material | Stainless steel |
Registration