Loadcells
Load cells convert weight, force, etc. to electrical signals. KYOWA strain-gage load cells are notable for simple structure, easy installation, high response and maintenance-free over long periods of usage.
- category select
- select category is auto scroll
- For Compression Load Measurement
- For Tension Load Measurement
- For Tension/Compression Loads
- For Component Force Measurement
- For Special Purposes
For Compression Load Measurement
Small-sized Load Cells
Small-sized Load Cells
| For Compression Load Measurement | Rated Capacity | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| N | kN | MN | ||||||||||||||||||||
| Model | 5 | 10 | 20 | 50 | 100 | 200 | 300 | 500 | 1 | 2 | 5 | 10 | 20 | 30 | 50 | 100 | 200 | 500 | 1 | 2 | 5 | |
| Small-sized Compression Load Cells |
Small-sized for load distribution measurement LMA-A |
● | ● | ● | ● | ● | ● | ● | ● | |||||||||||||
|
Ultra-small LMB-A |
● | ● | ● | ● | ● | ● | ||||||||||||||||
|
Ultra-small LMBT-A |
● | ● | ● | ● | ● | ● | ||||||||||||||||
|
Connector-Equipped LCX-A-ID |
● | ● | ● | ● | ● | ● | ||||||||||||||||
|
Stainless Steel Make LCN-A |
● | ● | ● | ● | ● | ● | ||||||||||||||||
|
Diameter: 21mm LMR-S-SA2 |
● | ● | ● | ● | ||||||||||||||||||
|
Small-sized Large-capacity Compression Load Cells |
Diameter: 20 or 25mm LCR-G-SA2 |
● | ● | ● | ● | |||||||||||||||||
Large-capacity
High-Accuracy
High-Accuracy
| For Compression Load Measurement | Rated Capacity | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| N | kN | MN | ||||||||||||||||||||
| Model | 5 | 10 | 20 | 50 | 100 | 200 | 300 | 500 | 1 | 2 | 5 | 10 | 20 | 30 | 50 | 100 | 200 | 500 | 1 | 2 | 5 | |
| High-Accuracy Load Cells |
Accuracy 1/2000 LC-V |
● | ● | ● | ||||||||||||||||||
|
Accuracy 1/5000 LCH-F |
● | ● | ||||||||||||||||||||
|
Large Capacity, Accuracy 1/1000 LCV-A |
● | ● | ||||||||||||||||||||
Beam-Type Load Cells
Beam-Type Load Cells
| For Compression Load Measurement | Rated Capacity | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| N | kN | MN | ||||||||||||||||||||
| Model | 5 | 10 | 20 | 50 | 100 | 200 | 300 | 500 | 1 | 2 | 5 | 10 | 20 | 30 | 50 | 100 | 200 | 500 | 1 | 2 | 5 | |
| Beam-Type Load Cells |
Compact andLightweight LUB-B |
● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |||||||||||
|
Accuracy:1/2000 LUB-C |
● | ● | ● | |||||||||||||||||||
Environmentally-resistant load cell
Environmentally-resistant load cell
| For Compression Load Measurement | Rated Capacity | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| N | kN | MN | ||||||||||||||||||||
| Model | 5 | 10 | 20 | 50 | 100 | 200 | 300 | 500 | 1 | 2 | 5 | 10 | 20 | 30 | 50 | 100 | 200 | 500 | 1 | 2 | 5 | |
| Compression Load Cells |
For High Temperature LC-FH |
● | ● | ● | ● | ● | ● | ● | ● | ● | ||||||||||||
| Corrosion-Resistant Compression Load Cells |
Stainless Steel LC-J |
● | ● | ● | ● | ● | ● | |||||||||||||||
| Explosion-Proof CompressionLoad Cells |
Explosion-Proof LCS-D |
● | ● | ● | ● | |||||||||||||||||
| Stainless Steel Load Cell |
For Food Tanks and Hoppers LCTS-B |
● | ● | ● | ● | ● | ● | |||||||||||||||
Thin Load Cells
Thin Load Cells
| For Compression Load Measurement | Rated Capacity | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| N | kN | |||||||||||||
| Model | 500 | 800 | 1 | 2 | 3 | 5 | 10 | 20 | 30 | 50 | 100 | 200 | 300 | |
| Thin Compression Load Cells |
As Thin as 25 to 50 mm in Total Height LCK-A |
● | ● | ● | ● | ● | ● | |||||||
| ThinLoad Cell |
For Tanks and Hoppers LCTA-A |
● | ● | ● | ● | ● | ||||||||
|
For Tanks and Hoppers LCTB-A |
● | ● | ● | ● | ● | |||||||||
|
For Tanks and Hoppers LCTE-A |
● | ● | ● | ● | ● | |||||||||
|
For Tanks and Hoppers LCTD-A |
● | ● | ● | |||||||||||
For Tension Load Measurement
High-temperature -10 to 150℃
Low-temperature -196 to 30℃
For Tension/Compression Loads
For Component Force Measurement
For Special Purposes
Load Cells for Steel making Line
Washer-Type Load Cells
LCW-D-S,E-S
For Rolling/Depressing Pressure Measurement under Harsh Envrionment
1 to 5 MN
Load Cells for Steel making Line
| For Special Purposes(Load Cells for Steel making Line ) | Rated Capacity | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| kN | MN | ||||||||||
| Model | 5 | 10 | 20 | 30 | 50 | 100 | 1 | 2 | 3 | 5 | |
| Tension Meter Load Cell |
For Tension Meter LCR-B-S7 |
● | ● | ● | ● | ● | ● | ||||
| Washer-TypeLoad Cell |
Washer-Type for Rolling Mill LCW-D-S |
● | ● | ● | ● | ||||||
|
Washer-Type for Rolling Mill LCW-E-S |
● | ● | ● | ● | |||||||
Crane Load Cells
Crane Load Cells
| For Special purposes | Rated Capacity | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| kN | MN | |||||||||||
| Model | 10 | 20 | 30 | 50 | 100 | 200 | 300 | 500 | 1 | 1.5 | 2 | |
| Pin-Type Load Cells |
For Pulley Axis of Crane LTP-S-S |
● | ● | ● | ● | ● | ● | |||||
| Crane Load Cells |
1 to 5V Output Available LTA-C-S |
● | ● | ● | ● | ● | ● | |||||
Special purposes
Special purposes
| For Special purposes | Rated Capacity | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| kN | MN | |||||||||||
| Model | 10 | 20 | 30 | 50 | 100 | 200 | 300 | 500 | 1 | 1.5 | 2 | |
| Washer-Type Load Cells |
Different Diameters Available LCW-C-SA3 |
● | ● | ● | ● | ● | ● | |||||
| Jack Load Cells |
For Jack LUR-B-SA1 |
● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| One-End Revolving Tension Load Cells |
For Rope TensionMeasurement LTR-S-SA1 |
● | ● | ● | ||||||||
| Rectangular Load Cells |
For Pillow Block Load LCD-A-S |
● | ● | ● | ||||||||
Registration
Please register for our website support when downloading files or documents.

